Trifocal Lens

Optiflex TRIO

Optiflex Trio is a hydrophobic diffractive-refractive trifocal intraocular lens used for presbyopia correction. Optiflex Trio is also available in toric version.

Its unique diffraction pattern gives balanced light distribution at all distances and results in spectacle independence for vision.

 

Optiflex TRIO

Features

  • Made in Ireland
  • Uninterrupted functional vision
  • Smooth transition between just 12 zones – minimizes glare and halos
  • Glistening free
  • Minimized dysphotopsia
  • Maximum light transmittance, which gives best quality vision in all lighting conditions
  • This lens’ unique material with natural yellow chromophore prevents the risk of Age Related Macular Degeneration (ARMD) and doesn’t distrub the circadian rhythm
  • Moreover, it doesn’t attribute to altered color perception, hence it enhances the contrast sensitivity

Optiflex TRIO

Technical Data Sheets

Model3FLA6
MaterialHydrophobic acrylic containing natural chromophore
Optic TypeSingle piece, diffractive-refractive, 360º square edge with aspheric optic
Near Addition+ 3.50 D
Intermediate Addition+ 1.85 D
Optic Size6.00 mm
Overall Size13.00 mm
Angulation
ACD5.28
Refractive Index1.48
Estimated Ultrasound A-ConstantSRK-T: 117.97
Recommended Optical A-ConstantsSRK-T: 118.37
SRK-II: 118.61
HOLLADAY 1 Const SF: 1.43
HOFFER-Q ACD: 5.22
HAIGIS: a0: 0.964, a1: 0.40, a2: 0.10
OLSEN ACD: 4.35
Diopter Range+7.0 D to +30.0 D (with 0.5 D steps)
Implantation SiteCapsular Bag
SterilizationIrradiation
Shelf life4 years from date of manufacture
Manufactured inIreland
Model3FLA6
MaterialHydrophobic acrylic containing natural chromophore
Optic TypeSingle piece, diffractive-refractive, 360º square edge with aspheric toric optic
Near Addition+3.50 D
Intermediate Addition+1.85 D
Optic Size6.00 mm
Overall Size13.00 mm
Angulation
ACD5.28
Refractive Index1.48
Estimated Ultrasound A-ConstantSRK-T: 117.97
Recommended Optical A-ConstantsSRK-T: 118.37
SRK-II: 118.61
HOLLADAY 1 Const SF: 1.43
HOFFER-Q ACD: 5.22
HAIGIS: a0: 0.964, a1: 0.40, a2: 0.10
OLSEN ACD: 4.35
Diopter Range+7.0 D to +30.0 D
(with 0.5 D steps)
Cylinder Range0.0 D a 6.0 D
(with 1.0 D steps between 0.0 D and 1.0 D - with 0.5 D steps between 1.0 D and 1.5 D - with 0.75 D steps between 1.5 D and 6.0D)
Implantation SiteCapsular Bag
SterilizationIrradiation
Shelf Life4 years from manufacturing date
Manufactured inIrland
ModelCylinder Power at IOL PlaneCylinder Power at Corneal PlaneRecommended Range of Corneal Astigmatic Correction
CYL-0.00 D0.00 D0.00 D0.00 D to 0.24 D
CYL-1.00 D1.00 D0.68 D0.25 D to 0.86 D
CYL-1.50 D1.50 D1.03 D0.87 D to 1.25 D
CYL-2.25 D2.25 D1.54 D1.26 D to 1.75 D
CYL-3.00 D3.00 D2.05 D1.76 D to 2.25 D
CYL-3.75 D3.75 D2.57 D2.26 D to 2.75 D
CYL-4.50 D4.50 D3.08 D2.76 D to 3.25 D
CYL-5.25 D5.25 D3.60 D3.26 D to 3.75 D
CYL-6.00 D6.00 D4.11 D3.76 D and above

Testimonial

Dr. Joaquim Cabot

In this interview, Dr. Joaquim Cabot (OftalmoPlus/IOCAB Clinic, Barcelona) tells us about his experience after the first 15 OPTIFLEX TRIO patients.

Testimonial

Dr. J.R. Soler Tomás

In this interview, Dr. Soler Tomás from the Oftalnova Clinic in Teknon, Barcelona, ​​speaks about the level of comfort reported by his patients, and his first experiences implanting the new OPTIFLEX TRIO trifocal lens.

Surgery Video

Implantation

Implantation of an Optiflex TRIO Lens.

Additional Documentation

Optiflex TRIO Brochure

OptiflexTrio-Weyezer-Brochure-Front

Other Products

Preloaded Monofocal IOL

Optiflex GENESIS Comfort NY

Phakic Lens

EyeCryl Phakic